Receptors are points you place in the model to record a detailed time series (every output step) at one location, saved as easy-to-open text/CSV files. They need to be opened in Excel/Python and cannot be opened in Leonardo.
Atmosphere receptor (.AT_1DT)
A time series, by height, of the air variables above (wind, temperature, humidity, turbulence, radiation, MRT, plant values, CO₂, and PET/UTCI if enabled).
Surface/Flux receptor (.FX_1DT)
A time series of the surface variables at that point (surface temperature, fluxes, radiation, comfort).
Soil receptor (.SO_1DT)
A time series, by depth, of soil temperature and water content.
Each column matches a parameter already explained in the corresponding section above.